Driveway advice. Published
How thick should a concrete driveway be?
The short answer
A residential concrete driveway in Australia should be at least 100 mm thick for cars and other vehicles under 3 tonnes gross mass, and at least 150 mm where vehicles of 3 to 10 tonnes will use it. Those are the minimums in Cement Concrete and Aggregates Australia's data sheet for residential driveways. The council crossing between your boundary and the kerb has its own figure, a minimum 100 mm in the City of Newcastle and 125 mm in Lake Macquarie.
- 75 mm
- Paths and patios, foot traffic only
- 100 mm
- Driveways for vehicles under 3 tonnes gross
- 125 mm
- Minimum crossing in Lake Macquarie
- 150 mm
- Vehicles of 3 to 10 tonnes gross
The thickness of a driveway is set by the heaviest thing that will stand on it, not by the finish, the colour or the mesh. The Australian reference for it is the data sheet Residential Concrete Driveways and Paths, published by Cement Concrete and Aggregates Australia (CCAA), the industry’s peak body. Its figures are below, followed by the two places they change in Newcastle and Lake Macquarie: at the council crossing, and under anything heavier than a car.
What thickness does each kind of slab need?
| Slab | Minimum thickness | Minimum mesh | Control joints no more than | Set by |
|---|---|---|---|---|
| Path or patio, foot traffic only | 75 mm | SL52 | 2 m apart | CCAA data sheet |
| Driveway, vehicles under 3 tonnes gross | 100 mm | SL72 | 3 m apart | CCAA data sheet |
| Driveway, vehicles of 3 to 10 tonnes gross | 150 mm | SL92 | 5 m apart | CCAA data sheet |
| Council crossing, City of Newcastle | 100 mm | SL72 | 3 m apart | Council drawing A1300 |
| Council crossing, Lake Macquarie | 125 mm | SL72 | Per council drawing | Council drawings EGSD 201 and 202 |
Anything heavier than 10 tonnes is outside the data sheet, which says such a pavement needs a design from a qualified engineer. The thickness is also a minimum everywhere, not an average. The data sheet’s wording is that it “should be maintained across the entire slab surface”, so a slab that is 100 mm at the edge form and 70 mm over a high spot in the base is a 70 mm slab.
Is your vehicle under 3 tonnes?
The 3 tonne line is gross mass, meaning the vehicle loaded, not empty. Most cars and medium SUVs sit well under it. The top of the four-wheel drive and ute market does not: a LandCruiser 300 leaves the factory with a gross vehicle mass of 3,280 kg, and a 79 Series is plated at 3,510 kg. The figure for your own vehicle is the GVM on its compliance plate.
Then think about what else will use the slab. A caravan or a boat on a trailer parks its weight on one or two axles in the same spot for weeks. A skip bin delivery, a removalist’s truck or a concrete truck for the next job out the back may cross the driveway only a few times, but each one is far heavier than a car. If any of those is likely, say so when the driveway is measured, because it is the difference between a 100 mm slab and a thicker one.
Want the thickness written on the quote? Plain concrete driveways run $95 to $130 per m² supplied and laid. One site measure covers the slab, the crossing and the vehicles it has to carry.
When is 125 mm or 150 mm worth paying for?
Three situations, in the order they come up around Newcastle and Lake Macquarie.
- A heavy vehicle lives on the slab. A large four-wheel drive, a caravan, a loaded work ute or a boat. Past 3 tonnes gross the published minimum is 150 mm, and this site’s specification asks for 125 mm where a boat trailer, a caravan or a heavy van will park.
- The crossing is in Lake Macquarie. Council requires at least 125 mm there whatever you drive. More on that below.
- The parking pad beside the driveway. A hardstand for a caravan or a trailer is sized for what parks on it, which can be heavier than the car on the driveway next to it. Hardstands are covered on the paths, slabs and patios page.
Thicker concrete is more concrete. A 36 m² single driveway holds 3.6 cubic metres at 100 mm, 4.5 at 125 mm and 5.4 at 150 mm, so going from 100 to 150 mm adds half as much concrete again, and the 150 mm slab steps up to heavier mesh as well. That is why thickness belongs on the written quote in millimetres. The cost guide explains what else moves a price.
Why is the council crossing a different thickness?
The strip between your front boundary and the kerb sits on council land, and each council writes its own standard for it. City of Newcastle’s standard drawing A1300 asks for a crossing at least 100 mm thick with SL72 mesh in the top of the slab and 25 MPa concrete. Lake Macquarie City Council asks for at least 125 mm, also SL72 and 25 MPa, dowelled into the kerb.
So a driveway in Charlestown, Cardiff or Belmont is commonly two thicknesses in one pour: 100 mm from the garage to the boundary and 125 mm from the boundary to the kerb. The crossing also needs council approval before it is poured, which the Section 138 guide sets out for both councils, and the areas page lists which suburbs fall under which rulebook.
Does mesh let you pour a thinner slab?
No, and the data sheet is direct about it: steel reinforcement “does not increase the load capacity of the pavement, or affect its thickness”. Its job is to hold tightly closed any cracks that form. What it does need is to be in the right place. The data sheet puts the mesh in the top half of the slab with at least 30 mm of concrete over it, supported on bar chairs no more than 800 mm apart, with sheets overlapped by two cross wires. Mesh laid on the ground and hooked up during the pour ends up on the ground.
Joints work with the mesh. For a 100 mm driveway the data sheet puts control joints at no more than 3 metres apart and keeps each panel’s long side to no more than one and a half times its short side.
What is under the slab matters as much
A thick slab on a soft base fails like a thin one. The data sheet warns against assuming concrete will bridge a poor subgrade, and says weak, wet or loose ground should come out and be replaced with compacted material. On highly expansive clay it recommends a non-expansive sub-base layer under the slab and gives 100 mm as the thickness for the majority of cases. Clay is the ground under most of the inland suburbs here, so the base is worth a question at the measure. Curing counts too. The data sheet asks for at least 3 days of curing, rising to 7 days within a kilometre of the coast, which takes in the streets nearest the beach in a suburb such as Merewether.
What should the concrete strength be?
The data sheet’s minimum for residential paving is N20, meaning 20 MPa. It recommends N25 where heavier vehicles use the slab, and both councils here require 25 MPa on the crossing. Because the crossing and the driveway are commonly poured together, the specification this site holds quotes to asks for 25 MPa throughout.
How do you check the thickness you are paying for?
- On the quote. Thickness inside the boundary and at the crossing, each in millimetres, plus the mesh size and the concrete strength. “Standard thickness” is not a number.
- Before the pour. The edge forms show the depth at the sides. Ask how the base level is checked in the middle, which is where a slab goes thin.
- In Newcastle. Council inspects the formwork for the crossing before any concrete is placed, so the crossing’s depth is checked by someone other than the person pouring it.
- When replacing. If an old driveway cracked because it was thin, the new one should not copy it. See removal and replacement.
A plain concrete driveway and an exposed aggregate driveway follow the same thickness rules. The finish changes the surface and the price per square metre, not the slab underneath.
Checked against
Sources for the figures on this page
- Cement Concrete and Aggregates Australia. Residential Concrete Driveways and Paths, data sheet, December 2017. Thickness by vehicle mass, concrete grade, Table 1 mesh and joint spacing, sub-base, cover, curing.
- City of Newcastle. Standard drawing A1300, Driveway Crossing Standard Design Details, revision 2. 100 mm minimum crossing, SL72 mesh, 25 MPa.
- Lake Macquarie City Council. Driveways page and engineering standard drawings EGSD 201 and 202. 125 mm minimum crossing, SL72 mesh, 25 MPa, dowelled to the kerb.
- Standards Australia. AS 3600 Concrete structures and AS 1379 Specification and supply of concrete. The standards the data sheet draws its strength grades and crack control steel from.
Written by Newcastle Driveway Concreters from the published documents above and last checked on 18 November 2026. This site is a referral service, not the contractor; the thickness, steel and concrete for your driveway are whatever the written quote states after a site measure. Standards and council drawings change, so the publisher's current document is the authority over this page.